CDCS BOOK FREE|HANDY FOR EXIN EPI CERTIFIED DATA CENTRE SPECIALIST

CDCS Book Free|Handy for EXIN EPI Certified Data Centre Specialist

CDCS Book Free|Handy for EXIN EPI Certified Data Centre Specialist

Blog Article

Tags: CDCS Book Free, New CDCS Exam Fee, CDCS Mock Exams, CDCS Valid Test Forum, Exam CDCS Guide Materials

If you are still struggling to prepare for passing CDCS certification exam, at this moment Real4dumps can help you solve problem. Real4dumps can provide you training materials with good quality to help you pass the exam, then you will become a good EXIN CDCS certification member. If you have decided to upgrade yourself by passing EXIN Certification CDCS Exam, then choosing Real4dumps is not wrong. Our Real4dumps promise you that you can pass your first time to participate in the EXIN certification CDCS exam and get EXIN CDCS certification to enhance and change yourself.

As a prestigious platform offering practice material for all the IT candidates, Real4dumps experts try their best to research the best valid and useful CDCS exam dumps to ensure you 100% pass. The contents of CDCS exam training material cover all the important points in the CDCS Actual Test, which can ensure the high hit rate. You can instantly download the CDCS practice dumps and concentrate on your study immediately.

>> CDCS Book Free <<

Pass-sure CDCS Study Materials are the best CDCS exam dumps - Real4dumps

The experts in our company are always keeping a close eye on even the slightest change in the field. Therefore, we can assure that you will miss nothing needed for the CDCS exam. What's more, the latest version of our CDCS study materials will be a good way for you to broaden your horizons as well as improve your skills. So with our CDCS Exam Questions, not only you can pass the exam with ease with 100% pass guarantee, but also you can learn the most professional and specilized knowledge in this field!

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q52-Q57):

NEW QUESTION # 52
What mainly affects the cooling capacity of a raised floor tile?

  • A. Type of ICT equipment, location of the air conditioner, pressure under the raised floor, allowable temperature in the hot aisle
  • B. Percentage of the surface opening, airflow direction of the ICT equipment, temperature difference between the air intake and air exhaust of the ICT equipment, construction material of the tile
  • C. Relative humidity in the computer room, temperature of the cold air, pressure under the raised floor, construction material of the tile
  • D. Percentage of the surface opening, obstruction of the supporting construction, pressure under the raised floor, damper construction

Answer: D

Explanation:
The cooling capacity of a raised floor tile is primarily influenced by the percentage of surface opening, the obstruction caused by the supporting construction, the pressure under the raised floor, and the damper construction. These factors dictate how much airflow can pass through the tile and how effectively cool air is distributed to the equipment in the data center.
Detailed Explanation:
The percentage of surface opening on a floor tile affects how much air can flow through, with larger openings allowing more airflow. Supporting structures beneath the floor can obstruct airflow, reducing cooling efficiency. Pressure under the raised floor impacts the velocity and volume of air that moves through the tile. Additionally, if dampers are installed, they control the airflow rate, which can be adjusted to meet specific cooling needs for the area.
EPI Data Center Specialist References:
EPI guidance on airflow management under raised floors emphasizes these factors as critical for effective cooling, especially in high-density areas. Ensuring unobstructed and adequate airflow helps maintain consistent cooling across equipment.


NEW QUESTION # 53
You need to determine the strategy for the cooling audit. All the servers are based on a front-to-rear (F-R) airflow design.
Which location for the temperature/humidity measurement should you recommend for the audit?

  • A. At the back/rear of the server at 50 mm/2 inch
  • B. At 1.5 meters/5 feet above the floor in the middle of the cold aisle
  • C. At 1.5 meters/5 feet above the floor in the middle of the hot aisle
  • D. At the front/intake of the server at 50 mm/2 inch

Answer: D

Explanation:
For a cooling audit in a data center, it is essential to measure temperature and humidity where air enters the servers to accurately assess cooling performance. In this case, since all servers have a front-to-rear (F-R) airflow design, measuring at the front/intake of the server will provide a precise understanding of the cooling conditions that the equipment is experiencing.
Detailed Explanation:
Servers with a front-to-rear airflow design draw in cool air from the cold aisle at the front, which is then exhausted into the hot aisle at the rear. By measuring temperature and humidity 50 mm/2 inches from the front intake, you gather data on the air conditions right before it enters the servers, providing an accurate representation of the cooling environment as it directly impacts the equipment.
Measuring in the cold aisle at the front intake ensures that the readings reflect the actual conditions of the incoming air that the servers depend on for effective cooling. This approach is consistent with best practices for maintaining thermal conditions in a data center, as it helps confirm that the cooling systems are delivering air within the required temperature and humidity specifications.
EPI Data Center Specialist References:
According to the EPI Data Center Specialist curriculum, the optimal placement for temperature and humidity sensors is at the intake of the equipment in the cold aisle, as it directly correlates to the environmental conditions affecting the servers. This positioning allows for a more effective audit of cooling performance, which is critical for maintaining the reliability and efficiency of the data center's operations.


NEW QUESTION # 54
An air-conditioner unit needs to be selected. Two types are available:
Unit-A has a Sensible Heat Ratio (SHR) of 0.7.
Unit-B has a Sensible Heat Ratio (SHR) of 0.9.
From an efficiency point of view, which one should be selected?

  • A. Not relevant, as Sensible Heat Ratio is only specified for air-conditioner equipment to indicate the ratio between intake temperature and exhaust temperature.
  • B. It does not matter, as the Sensible Heat Ratio has nothing to do with efficiency.
  • C. Unit A
  • D. Unit B

Answer: D

Explanation:
From an efficiency standpoint, Unit B with a Sensible Heat Ratio (SHR) of 0.9 is preferable. A higher SHR indicates that a greater proportion of the air conditioner's capacity is dedicated to sensible cooling (temperature reduction) rather than latent cooling (moisture removal). In data centers, sensible cooling is more critical since IT equipment primarily generates heat without adding significant moisture.
Detailed Explanation:
An SHR of 0.9 means that 90% of the cooling capacity is used for sensible cooling, which is more efficient for environments like data centers where humidity control is typically less of a concern. Opting for an air conditioner with a higher SHR ensures that most of the cooling energy is focused on temperature reduction, making Unit B more efficient in this scenario.
EPI Data Center Specialist References:
EPI data center best practices recommend choosing cooling units with higher SHR values in data centers, as they better match the cooling needs of IT equipment. High SHR units improve cooling efficiency by concentrating on sensible heat removal, which is vital for maintaining the optimal thermal environment.


NEW QUESTION # 55
The data center has been in operation for about 1 year and 2 months. The dust levels in the computer room are relatively high.
What is the most likely root cause?

  • A. Low pressure in the computer room
  • B. Every computer room has high dust levels due to constant high-speed air movement
  • C. Floorboards are most likely not fitted correctly
  • D. The cleaning crew is not doing their work properly

Answer: C

Explanation:
High dust levels in a computer room are often due to improperly fitted floorboards. When floorboards are not securely installed or do not fit tightly, they allow dust and particles from the subfloor to enter the room. In a data center, this can lead to high levels of dust that affect air quality and equipment performance.
Detailed Explanation:
Raised floors in data centers can accumulate dust and debris, especially if the floorboards are not properly sealed. Loose or improperly fitted floorboards allow contaminants from the subfloor to enter the data center environment, increasing the dust levels over time. Proper installation and maintenance of floor panels are essential to prevent dust infiltration and maintain clean conditions.
EPI Data Center Specialist References:
EPI training emphasizes proper flooring installation and maintenance to control air quality within data centers. Correctly fitted floorboards prevent dust accumulation from the subfloor, which helps protect sensitive equipment and maintains a cleaner environment.


NEW QUESTION # 56
What is the minimum requirement for the power feeds to the building for a Rated-3 data center based on the ANSI/TIA-942 standard?

  • A. One feed from one substation split over two separated distribution boards in separate rooms
  • B. Two feeds coming from two different substations, one power company is acceptable
  • C. Two feeds entering the data center building from one substation
  • D. Two feeds coming from two different substations, one power company is not acceptable

Answer: B

Explanation:
The minimum requirement for power feeds to a Rated-3 data center according to ANSI/TIA-942 is to have two independent power feeds, which can come from two different substations provided by the same power company. This ensures redundancy and concurrent maintainability, as each feed can support the load independently during maintenance or failure of the other.
Detailed Explanation:
The separation by two substations ensures resilience in case of a localized outage or substation maintenance, aligning with Rated-3 requirements for uninterrupted operation. ANSI/TIA-942 permits these feeds from a single utility provider as long as they are supplied from distinct substations.
EPI Data Center Specialist References:
EPI underscores the importance of dual power feeds from separate substations for Rated-3 facilities, highlighting that the ability to draw from different substations aligns with redundancy requirements for high availability.


NEW QUESTION # 57
......

We can assure to all people that our study materials will have a higher quality and it can help all people to remain an optimistic mind when they are preparing for the CDCS exam, and then these people will not give up review for the exam. On the contrary, people who want to pass the exam will persist in studying all the time. We deeply believe that the CDCS Study Materials from our company will is most suitable and helpful for all people.